SePem 100 / 150
SePem 100 / 150
+
  • SePem 100 / 150
  • SePem 100 / 150

SePem 100 / 150

Leaks in water pipe networks can result in significant water losses. Thanks to systematic monitoring of the network with SePem® data loggers, you can reliably identify existing leaks and catch new ones early on – much faster than with conventional methods.

Classification:

Order Number:

090

Product model:

  • Host Capability
    • Commodity name: SePem 100 / 150
    • Commodity ID: 090

    Leaks in water pipe networks can result in significant water losses. Thanks to systematic monitoring of the network with SePem® data loggers, you can reliably identify existing leaks and catch new ones early on – much faster than with conventional methods.

    Detect water losses early

    Leaks in water pipe networks can result in significant water losses. Thanks to systematic monitoring of the network with SePem® data loggers, you can reliably identify existing leaks and catch new ones early on – much faster than with conventional methods.

    SePem 100 / 150SePem 100 / 150

    Systematic leak detection

    The SePem® system comprises the SePem® 01 Master receiver as well as any number of data loggers; the SePem® 100s are preferable for mobile use whereas the SePem® 150s are designed for permanent use. They are magnetically attached to valve rod extensions, or to hydrants or other fittings in the pipe network. The microphone integrated in the logger converts the structure-borne noise in the line to a sound signal. This is cyclically recorded during times of low consumption – usually during the night between approx. 2:00 am and 4:00 am, when there is very little sound interference in the surrounding area, if any. On a leak-free line the noise level measured during this time is virtually zero. If there is a leak in the pipeline, the noise logger will measure values much different to zero, thus indicating a leak.

    SePem® 100: data loggers for mobile use

    The SePem® 100 data loggers with integrated aerial are perfect for mobile use in the water pipe network. They are placed on fittings at measuring points in a specified section of network and record the level for a programmable period of time during the night – usually half an hour. The loggers are collected in the next day. The measurement data is transmitted to the SePem® 01 Master by radio. Noticeably high measurement values indicating a leak are immediately flagged up by an audible signal. This is a reliable way of detecting existing leaks. The data loggers are then successively inserted in other sections of the network until the whole network has been checked.

    SePem® 150: safety through permanent monitoring

    The SePem® 150 data loggers are designed for the stationary monitoring of water supply networks. They have an external aerial and are permanently fixed to fittings. The SePem® 150s record the minimum level every night for a programmable period of time, for example half an hour. The locations are periodically patrolled, for instance daily or weekly, when the noise loggers send their data telegrams to the SePem® 01 Master. Unlike the mobile application, there is no comparison of the absolute levels of two measuring points, but rather a relative change in the level at a measuring point means that a new leak can be very quickly identified.

    Sturdy technology you can rely on 

    • The data loggers feature the high protection class IP68. The housing is made of stainless steel and a special, tried and tested plastic, which is also used, for example, in the housing of pumps used in sewage treatment. This makes the SePem® 100 and SePem® 150 totally waterproof and dustproof, resistant to all corrosion and other stresses and suitable for use in all environments.
    • With a battery life of many years, the SePem® 100s and SePem® 150s are operational for a long time and are equipped for any task. 

    Reliable and efficient 

    • The SePem® 100 and SePem® 150 data loggers feature highly sensitive Piezo microphones, which are specially optimised for leak detection and can pick up noises over very large distances.
    • The data can be read out easily by bidirectional radio. In the case of the permanently installed SePem® 150 loggers, you do not need to open the covers; simply drive by with the SePem® 01 Master to record the data.
    • As well as the minimum level, the transmitted telegram contains the width and frequency of the noise and is clearly displayed on the SePem® 01 Master screen. There are additional options for verifying the measurement results, for example by precluding sound interference such as rain, traffic, power lines etc.
    • During the patrol, a full data set containing the plot of the last measurement can also be retrieved at the touch of a button from every SePem® 150 logger in addition to the data telegram. Again, it is not necessary to open the manhole cover to obtain all of this data. A brief pause within the radio range of the SePem® 150 is sufficient. 

    Convenient to use 

    • The online measurement function allows you to take current measurements on site which can be displayed on the SePem® 01 Master. For example, this means that you can check the suitability of measuring points during the day at the time of installation before the actual measurement at night or determine appropriate installation intervals. Or you can verify the plausibility of measurement data collected overnight directly on site.
    • The measuring times and periods of radio activity are freely programmable.
    • The SePem® 01 Master, with its simple and intuitive menu navigation, provides fast and reliable results and can also be reliably operated by less experienced users.

Purchase Consultation

* Note: Please be sure to fill in the information accurately and keep the communication unblocked. We will get in touch with you as soon as possible.

Security verification
Submit Message

Other Products


Cover locator M 130

The M 130 valve box locator detects at depth and is not sensitive to surface metals, moisture or fluctuations in temperature. One button operation makes it easier to use the device;

SeFlow 400

The SeFlow 400 is Sewerin’s single channel portable flowmeter for applications in the municipal water and wastewater sector offering long term stable and precise bidirectional flow measurements in remote areas outdoor.

FerroTec FT 10

The FerroTec FT 10 helps you safely and reliably locate concealed shaft covers, sliding rods and caps, as well as pavement markers and other objects. The only requirement is that they are made of iron, cast iron or steel. The ergonomic design, convenient operation and precise measuring technology make your work fast and easy.

VARIOTEC 460 Tracergas

The VARIOTEC® 460 Tracergas was developed especially for leak detection on underground pipes by using tracer gas. It is characterised by an outstanding price to performance ratio.

Glass fibre probe system

Non-metal pipes can be detected if the glass fibre rod can be inserted into the pipe in question. The rod is equipped with a copper strand so that it can be energized by a pipeline locating system such as FERROPHON® or UtiliTrac® using a generator and then detected using a receiver. In this way, the path of the pipe in question can be determined quickly and exactly to the last meter.

System Combiphon

Plastic pipes cannot be located by conventional electromagnetic means because they are not electroconductive. A different principle is applied when locating pipes using the acoustic method: The pipes transmit mechanical vibrations better than the earth that surrounds them.

Operator:010-5780 7006
Fax: 010-5780 7007
Email:info@polytide-bj.com


After-sales service:010-5608 1888
After sales complaints:complain@polytide-bj.com
Pay attention to our WeChat service number and contact us directly.

Focus on usFocus on us

Follow Polytide

Get more updates